Concrete testing software

Concrete testing software for small labs

Cylinder strength with the L/D correction, ACI 318 acceptance across every running average, and plain-English guides to C39, C31 and fresh concrete tests. Built for concrete quality control in labs of 1 to 20 people, in psi, inches and pounds-force.

Free calculators. No sign-up. They run in your browser and save nothing.

By Last reviewed:

Key takeaways

  • Strength = max load ÷ (π × D² ÷ 4), with D from two diameters at right angles.
  • L/D at or below 1.75 is corrected; below 1.00 is flagged, not reported.
  • ACI 318: every running average of three tests ≥ f'c, and no single test below its limit.
  • Fresh concrete and curing records explain low breaks before cores are needed.
CMT lab workflowField test, lab data, calculation, review and report.01Field reportSlump, air, temp02BreaksDue-date schedule03CalculateTested library04ReviewApprove and lock05ReportPDF to the client
A concrete workflow: field report, scheduled breaks, calculation, review and the report sent to the client.

Calculated live by the library

What does a reviewer see for each test?

Cylinder break, 6 × 12 in
sample input
Average diameter
6.01 in
Area
28.37 in²
L/D
2.00No correction
Strength
4,230 psi
4 × 8 in at 50,000 lbf
3,980 psi
D1 6.00, D2 6.02 in, 120,000 lbfOpen calculator
ACI 318 acceptance, f'c 4,000 psi
sample input
Test 1 average
4,125 psi
Test 2 average
3,650 psi
Test 3 average
4,275 psi
Running average of 3
4,017 psipass
Single-test limit 3,500 psi
lowest checkedpass
Three 28-day tests, 6 × 12 inOpen calculator

How we handle the math

How does ProofGrit handle the math?

Every calculator on this site uses one tested calculation library. The rules below are the ones it follows.

  1. 01

    Two diameters, always

    Area comes from the average of two diameters measured at right angles, never from the nominal size.

  2. 02

    L/D correction, or a clear flag

    Short specimens are corrected by interpolation between the table values. Below an L/D of 1.00 the result is flagged, not reported.

  3. 03

    Round once, at the end

    Strengths stay at full precision through every average. Only the reported value is rounded to the nearest 10 psi.

  4. 04

    Every running average counts

    Acceptance checks each group of three consecutive tests, not just the latest, plus the single-test limit for your f'c.

FAQ

Frequently asked questions

What can I use today?

The concrete compressive strength calculator and the ACI 318 acceptance calculator, plus the guides on this page. They are free and run in your browser.

Are my results saved?

No. The calculators keep nothing. Copy or print the results into your own records.

Does it handle 4 × 8 and 6 × 12 cylinders?

Yes. The strength math works for any size, and the acceptance check applies the cylinder count rule for each size: at least two 6 × 12 or at least three 4 × 8 per test.

Which single-test limit is used?

f'c − 500 psi when f'c is 5,000 psi or less, and 0.90 × f'c above 5,000 psi.

Can I trust the math?

Each formula is shown on the calculator page, and the library is covered by automated tests against known results. You can retrace any number by hand.

Wondering if ProofGrit fits your lab?

Tell us what you test and how many people run it. The team replies by email.